High Elasticity:
Stretch Resistance

Thick Design:
Puncture Resistant

Sealed &Waterproof:
Care for Your Hands

Latex and allergy free:

These gloves have latex free materials that are useful for those people who have allergy to the latex. 

Puncture resistant:

Nitrile gloves are specifically manufactured in a puncture-proof technology. 

Full-proof sensitivity:

These are produced to fulfill sensitivity requirements.

Permeability of Surgical Gloves to Seven Chemicals ...- breakthrough times for gloves ,In this study breakthrough times were measured for surgical gloves with chemicals which are commonly used in healthcare. Classical methods of analytical chemistry were tailored for the permeation tests, which were carried out according to the European …Guide to Chemical-Resistant Best GlovesAll breakthrough times are normalized to the ASTM Re-quirements of 0.1 µg/cm2/min for the safest possible data. Such factors as temperature may accelerate the permeation and degradation of glove materials. ASTM F739, F1383 and EN 374 testing was performed as described in the standards at room temperature or 250 C. BEST GLOVES MEET YOUR NEEDS



GHS SDS Preparation Tip 1: How to Select Gloves for Chemicals

Here is a general guide for choosing the breakthrough time of a glove. The minimum requirement is that the breakthrough time of a glove should be bigger than the duration of expected exposure. > 8 hours: excellent. If a worker needs to wear the same gloves all day (i.e, 8 hours per day), a breakthrough time bigger than 8 hours is usually ...

Kimberly-Clark Nitrile Gloves - Dartmouth College

• The permeation breakthrough time is not recommended and the chemical has either high or low volatility. A glove/chemical combination receives a GREEN rating if: • The permeation breakthrough time is excellent or good and the chemical has high volatility. — OR — • The permeation breakthrough time is excellent and the chemical has

ansell chemical resistance guide for the breakthrough time

YELLOW: The glove is suitable for that applicationunder careful control of its use. 0000001749 00000 n 0000074945 00000 n Chemical Resistance Ratings 0 10 minute breakthrough time 1 ≥ 10 minute breakthrough time 0000073895 00000 n The ratings range from 0 to 6 with 6 being the best choice. 0000002026 00000 n 0000009430 00000 n %PDF-1.6 % ...

Chemical gloves and breakthrough times - IOSH forums home

Jun 30, 2017·Manufacturers' published permeation breakthrough times are virtually meaningless in establishing the actual permeation breakthrough times when gloves are used. In the first place they are based on a laboratory test according to EN374, which is itself flawed as the test is done at room temperature as opposed to skin temperature.

eLCOSH : Chemical Glove Selection

A rule of thumb is that double the thickness will quadruple the breakthrough time. The manufacturing process of glove making may result in slight variations in performance. The user is warned to exercise care and to check the glove regularly for breakthrough and diminished physical performance.

Evaluating Chemotherapy Protection for Exam Gloves

Kimberly-Clark believes that printing pertinent chemotherapy information on exam glove packaging including drugs tested against, breakthrough times and test method not only meets current regulatory requirements, but empowers glove users to understand the level of protection they are getting when they select an exam glove for use in chemotherapy.

Gloves Chemical Resistance Chart | Gloves By Web

This chemical resistance chart is for advisory use only. Conditions, exposure times, chemical concentrations and residues may effect glove performance. It is strongly advised that on-site testing of all gloves is important to determining safe usage.

Gloves Selection Using ANSI-ISEA-105-2016 - Grainger KnowHow

Standard Breakthrough Time (minutes) 0 < 10: 1 ≥ 10: 2 ≥ 30: 3 ≥ 60: 4 ≥ 120: 5 ≥ 240: 6 ≥ 480: Longer times indicate better chemical permeation resistance. Chemical Degradation. Degradation resistance testing measures the effects of a chemical on a glove. In this test, the measured effect is the loss of puncture resistance by ...

Understanding glove certification - Kimberly-Clark

Those gloves which do not meet the test standard can claim low chemical protection according to EN374-1:2003 EN374-3:2003 A, K, L Protection from Harsh Chemicals (immersion protection) The glove should achieve a breakthrough time of >30 minutes on at least 3 of the following chemicals:

Chemical and Liquid Resistant Gloves Buying Guide | Magid

The situation is similar with gloves. A combination of a short breakthrough time and a low permeation rate may expose a glove wearer to less chemical than a combination of a longer breakthrough time and a much higher breakthrough rate, if the glove is worn …

Chemical gloves and breakthrough times - IOSH forums home

Jun 30, 2017·Manufacturers' published permeation breakthrough times are virtually meaningless in establishing the actual permeation breakthrough times when gloves are used. In the first place they are based on a laboratory test according to EN374, which is itself flawed as the test is done at room temperature as opposed to skin temperature.

Chemical Compatibility Guide for: Best® N-Dex® Free Gloves

May 20, 2008·2. Breakthrough Detection Time (BDT): is the time in minutes after initial exposure of the glove to the test chemical to the time when the chemical is first detected on the inside of the glove. 3. Permeation Rate: is the steady state rate of a chemical in micrograms / minute permeating an area (cm2) of glove material.

Chemical Resistance of Gloves – Quick guide

Toluene nitrile (8 mil), double glove viton, polyvinyl acetate (PVA) Trichloromethyl Chloroformate (diphosgene) nitrile (8 mil) over butyl rubber glove box gloves Material must be used in a glove box. Triton-X 100 nitrile (8 mil), double glove Uranium Salts nitrile Xylene nitrile polyvinyl acetate (PVA), viton ...

Chemical Protective Clothing - Glove Selection : OSH Answers

Breakthrough time is time it takes a chemical to permeate completely through the material. It is determined by applying the chemical on the glove exterior and measuring the time it takes to detect the chemical on the inside surface. The sensitivity of the analytical instruments used in these measurements influence when a chemical is first detected.

Chemical Protective Clothing - Glove Selection : OSH Answers

Breakthrough time is time it takes a chemical to permeate completely through the material. It is determined by applying the chemical on the glove exterior and measuring the time it takes to detect the chemical on the inside surface. The sensitivity of the analytical instruments used in these measurements influence when a chemical is first detected.

Chemical Protective Clothing - Glove Selection : OSH Answers

Breakthrough time is time it takes a chemical to permeate completely through the material. It is determined by applying the chemical on the glove exterior and measuring the time it takes to detect the chemical on the inside surface. The sensitivity of the analytical instruments used in these measurements influence when a chemical is first detected.

Permeation breakthrough times according to ... - Work Gloves

Permeation breakthrough times according to EN374-3:2003 (minutes) Glove : TouchNTuff® 93-300 Permeation breakthrough times according to EN374-3:2003 (minutes) ... Data given in the table above are based on results of laboratory tests performed on the palm area of the glove or are based on extrapolations from the results of laboratory tests ...

Chemical Resistance of Gloves – Quick guide

Toluene nitrile (8 mil), double glove viton, polyvinyl acetate (PVA) Trichloromethyl Chloroformate (diphosgene) nitrile (8 mil) over butyl rubber glove box gloves Material must be used in a glove box. Triton-X 100 nitrile (8 mil), double glove Uranium Salts nitrile Xylene nitrile polyvinyl acetate (PVA), viton ...

Understanding glove certification - Kimberly-Clark

Those gloves which do not meet the test standard can claim low chemical protection according to EN374-1:2003 EN374-3:2003 A, K, L Protection from Harsh Chemicals (immersion protection) The glove should achieve a breakthrough time of >30 minutes on at least 3 of the following chemicals:

Chemical protection | Guide Gloves

The table with permeation breakthrough times, for our chemical protection gloves, gives a recommendation of which glove that’s best suitable for different kind of chemicals. The higher number (breakthrough time in minutes), the longer you can wear the glove until chemical breakthrough.

GHS SDS Preparation Tip 1: How to Select Gloves for Chemicals

Here is a general guide for choosing the breakthrough time of a glove. The minimum requirement is that the breakthrough time of a glove should be bigger than the duration of expected exposure. > 8 hours: excellent. If a worker needs to wear the same gloves all day (i.e, 8 hours per day), a breakthrough time bigger than 8 hours is usually ...

Lab Glove Selection Guide - Harvard University

Breakthrough Time for the glove materials. Breakthrough times are usually determined under conditions of constant contact under pressure and may underestimate performance in laboratories. Where manufacturers provide breakthrough times specifically based on intermittent contact testing, these values are used. The gloves included in the Glove ...

Glove Material Breakthrough Time after Total Immersion ...

Glove Material Breakthrough Time after Total Immersion (times given in minutes) Legend Break through time less than 15 minutes Break through time equal to or more than 15 minutes and less than 180 minutes Break through time equal to or more then 180 minutes Chemical Name DOT Class Cate-gory Nitrile Neo-prene Latex Acetaldehyde 3 A 4 10.2 4

Chemical Resistance Guide - Honeywell

• Breakthrough time (BT)is defined as the elapsed time between initial contact of the liquid chemical with the outside surface of the glove and the time at which the permeation rate reaches 0.1 mg/m2 /sec. WHEN BREAKTHROUGH OCCURS, THE GLOVE IS NO LONGER PROVIDING ADEQUATE PROTECTION. • Permeation rate (PR), measured in milligrams per